Metallurgical Final Electromagnetic Stirrer (FEMS) for Steel Continuous Casting
You are here: Home » Products » Electromagnetic Stirrer » Metallurgical Final Electromagnetic Stirrer (FEMS) for Steel Continuous Casting

loading

Share to:
sharethis sharing button

Metallurgical Final Electromagnetic Stirrer (FEMS) for Steel Continuous Casting

Our metallurgical final electromagnetic stirrer (FEMS) is designed to improve steel quality during the final solidification stage of continuous casting. Manufactured with high-quality sintered wire, the coils offer excellent resistance to water, flushing and elevated temperatures. Advanced three-dimensional electromagnetic field analysis optimizes magnetic field distribution and stirring efficiency.
Availability:
Quantity:
  • JDFR

  • Zhongke

  • 8479820000

Product Overview

Our JDFR series final electromagnetic stirrer is designed to regulate residual molten steel flow near the final solidification zone of continuous casting machines (CCM). Through controlled electromagnetic stirring, it helps improve the internal solidification structure, reduce metallurgical defects and enhance steel quality.

Applications

The metallurgical FEMS is suitable for continuous casting operations requiring improved internal steel quality and production efficiency. We provide customized electromagnetic stirring solutions for both newly installed and existing continuous casting machines.

Features and Advantages

High-Quality Sintered Wire Coils

The coils are manufactured using high-quality sintered wire with excellent resistance to water, flushing and high temperatures, supporting reliable operation in demanding metallurgical environments.

Optimized Electromagnetic Field Distribution

Advanced 3D electromagnetic field simulation technology is adopted to optimize magnetic field distribution and improve stirring effectiveness.

Enhanced Steel Surface and Subsurface Quality

Helps minimize metallurgical defects and improve the overall quality of continuously cast steel.

Improved Solidification Structure

Promotes a more uniform internal structure while reducing centerline segregation and central porosity.

Enhanced Central Soundness

Improves the internal quality of cast strands through controlled stirring during the final solidification stage.

Customized Equipment Design

Our electromagnetic stirrers can be individually engineered to accommodate new and existing continuous casting machines.

Energy-Saving Design

The optimized electromagnetic configuration improves energy utilization during stirring operations.

Technical Parameters of FEMS

No.

Model

Voltage (V)

Current (A)

Frequency (Hz)

Flow (m³/h)

Dimension (mm) (In. Dia./Out. Dia. × H)

Weight (kg)

1

DJFR-340S

460

200

1-20(17)

15

φ340/φ640×820

918

2

DJFR-380S

400

500

7-9(9)

15

φ372/φ670×700

825

3

DJFR-430S

400

600

2-11(8.5)

20

φ420/φ720×750

917

4

DJFR-480S

400

600

1-20(6.5)

25

φ480/φ700×850

873

5

DJFR-520CE

400

600

7.3

2.4 (coil) + 6 (shell)

φ520/φ910×790

1395

6

DJFR-540S

500

600

4-10(6)

25

φ540/φ822×826

1084

7

DJFR-620CH

500

600

8

4 (coil) + 7 (shell)

φ616/φ1030×790

2355

8

DJFR-630S

400

800

6.8

30

φ630/φ1000×999

1778

9

DJFR-750S

500

800

6

28

φ750/φ1100×835

2011

10

DJFR-770S

159

550

9

30

φ770/φ1040×1000

2037

11

DJFR-800S

460

800

6

30

φ800/φ1154×985

2208

12

DJFR-880S

360

1200

6

50

φ880/φ1200×1000

2211

13

DJFR-1000S

370

550

3-5

50

φ1000/φ1299×1000

2450

14

DJFR-330CE

400

400

7-12(10)

1.2 (coil) + 4 (shell)

φ328/φ692×600

877

15

DJFR-360CE

400

700

9

2.2 (coil) + 6 (shell)

φ350/φ740×650

1018

16

DJFR-380CE

400

450

9

1.2 (coil) + 4 (shell)

φ370/φ750×600

1018

17

DJFR-430CE

400

700

4-10(8)

1.3 (coil) + 5 (shell)

φ430/φ802×820

1323

18

DJFR-470CE

500

600

8

2.1 (coil) + 5 (shell)

φ470/φ870×770

1131

19

DJFR-540CE

400

600

6.5

2.4 (coil) + 6 (shell)

φ540/φ900×770

1394

20

DJFR-570CE

500

700

1-16

5 (coil) + 6 (shell)

φ570/φ970×658

1506

21

DJFR-620CH

500

600

8

4 (coil) + 7 (shell)

φ630/φ1030×630

2355

22

DJFR-670CH

500

600

3-8

7 (coil) + 9 (shell)

φ670/φ1080×630

2578

23

DJFR-685C

500

600

5-9(7)

4 (coil) + 7 (shell)

φ685/φ1090×650

2009

24

DJFR-800CH

500

800

6

5 (coil) + 8 (shell)

φ896/φ1425×600

2355

25

DJFR-1100CH

500

800

1-10(6)

7 (coil) + 11 (shell)

φ1096/φ1610×650

3900

FAQ

Q: What is the main purpose of a metallurgical final electromagnetic stirrer?

A: FEMS regulates residual molten steel movement during final solidification to improve the internal quality of continuously cast steel.

Q: What materials are used in the electromagnetic stirrer coils?

A: Our coils are manufactured using high-quality sintered wire with resistance to water, flushing and elevated temperatures.

Q: How is the electromagnetic field distribution optimized?

A: We use advanced three-dimensional electromagnetic field analysis to optimize magnetic field distribution and improve stirring efficiency.

Q: Can the FEMS be customized for existing continuous casting machines?

A: Yes. We offer customized equipment designs based on continuous caster configurations and metallurgical requirements.

Contact us for customized final electromagnetic stirring solutions based on your continuous casting conditions and steel quality requirements.


Previous: 
Next: 

Product Category

 
Zhongke Electric is committed to R&D and providing complete solution for electromagnetic metallurgy, as well as on-line heating system for continuous rolling.

Navigation

Product Category

Contact Us

  Contact Person: Eric Wang
  Tel: +86-730-8688890
  Phone: +86-15173020676
  E-mail: wangfp@cseco.cn
 Copyrights 2021 Hunan Zhongke Electric Co., Ltd. All rights reserved. Supported by Leadong.